Eecps Machine for Cardiac Rehabilitation with Automatic System
Non-invasive EECPS Machine for cardiac rehabilitation with automatic system Our main products include gait training seri
Basic Info.
Treatment Pressure | 5-400mmhg |
After-Sale Service | Online Technical Support |
Origin | China |
HS Code | 94029000 |
Production Capacity | 5000 |
Product Description
Non-invasive EECPS Machine for cardiac rehabilitation with automatic system
Our main products include gait training series, upper limb rehabilitation training, lower limb rehabilitation series, lumbar and neck traction series, physical therapy series, occupational therapy series, treatment table series and children rehabilitation series.
* EECP stands for Enhanced External Counter Pulsation therapy.* It's an alternative method to relieve heart pain by creating new vessels(collaterals) in the heart by pushing blood into the
heart.
* EECP helps grow new collaterals for blood to flow, like a natural bypass around blocked arteries.
* EECP is a non-invasive, no pain, no side-effect treatment.
Type | Rehabilitation equipment |
Product name | Limbs Rehabilitation Device |
Application | Clinic,Hospital,Rehabilitation Center |
Size | 1660*750*330mm |
ECG Amplifier: | Input impedance: >2MΩ Common-mode rejection ratio: >80dB Bandwidth: 1-20 Hz on display |
SpO2 Oxygen Saturation: | Oxygen saturation range: 0 to 100% Accuracy SpO2 (±1 Saturation Deviation) 60-100% ± 2 digits for adults using the Finger Clip Sensor 60-100% ± 3 digits for adults using Flex or Reflectance Sensor 60-100% ± 4 digits using Ear Clip Sensor |
Triggering Method: | External trigger: R-wave of patient ECG External trigger ratio: 1:1 or 1:2 ECG triggers range: 35-125 ± 1 bpm |
Filter Technique: | Low-pass digital filter eliminates 50/60Hz and high-frequency interference |
Treatment Pressure Range: | Adjust from 5-400 mmHg |
Cuffs: | 1 Set--Calves, lower thighs, and upper thigh/buttocks |
Treatment Session Time Setting: | Set treatment time from 5 to 120 minutes maximum. System automatically stop when set time expires. |
System Protection: | Three circuit breakers -Mains and Compressor, and an emergency stop button. Multiple auto-protections, fully guarantee treatment safety. |
Electrical Performance: | Power Requirements: 220V±22V AC, 50/60Hz, 1200VA |
System Dimension: | Dimension: 2000mm×800mm×700mm Net Weight: 220 kg |
Operating Environment: | Temperature 50 to 95ºF (10°C to 35°C ) Relative Humidity <80% (no condensation) Atmospheric Pressure 700 to 1060 hPa Atmospheric Free of corrosives gas |
Transport and Storage Environment: | Temperature -40 to 131ºF (-40 °C to 55°C) Relative Humidity <95% (no condensation) Atmospheric Pressure: 500 to 1060 hPa Atmospheric Free of corrosive gas |